Bandung, Jawa Barat
Serving: Bandung, Cimahi, Bandung Barat +1 more
Home rooftop solar for R-1 1300 VA, 2200 VA, up to R-2 5500 VA homes. 1:1 net metering under Permen ESDM 2/2024 — daytime surplus is automatically exported to the PLN grid.
Electricity tariffs are rising, the climate is getting hotter, and solar panel prices have fallen — a more favorable market than 10 years ago.
PLN tariffs have risen an average of 3.5%/year historically. A 2200 VA home paying Rp 2 juta/month today could pay Rp 2,8 juta/month in 10 years without a solution.
Power cuts in the middle of working from home, the AC dying overnight while you sleep, freezer food spoiling. Solar + battery backup helps keep critical loads running (backup capacity depends on battery sizing).
Every kWh from PLN emits ~0,87 kg CO₂. A 5 kWp home rooftop system cuts ~7 tons of CO₂/year — equivalent to planting 350 trees.
1:1 net metering under Permen ESDM 2/2024 — surplus electricity becomes kWh credit to use at night.
Mono PERC solar panels convert sunlight into DC electricity. They work optimally in Indonesia's tropical climate, and even on cloudy days still produce 30-50%.
A string inverter converts the panels' DC electricity into 220V/single-phase AC used by all Indonesian household appliances.
AC power flows directly to the fridge, AC, lights, phone chargers, and TV. This self-consumption delivers the biggest savings.
Excess daytime electricity is exported to the PLN grid via the EXIM smart meter. The 1:1 net-metering scheme under Permen ESDM 2/2024 — kWh credit used at night.
Understand what you're buying — from the panels to PLN's EXIM smart meter.
Tier-1 modules with 21%+ efficiency and a 25-year performance warranty. 1 panel = ~0,55 kWp; a 5 kWp system needs 10 panels.
Brands like Huawei, SolarEdge, or SMA. Built-in WiFi monitoring, active anti-islanding, 5-10 year warranty.
Corrosion-resistant aluminum rail + roof hook/L-foot system. Compatible with ceramic tile, metal, concrete, or flat-deck roofs.
UV-resistant PV1-F solar cable, MC4 connectors, DC SPD surge protector, AC MCB, and system grounding.
A bidirectional export-import meter installed by PLN free of charge once the SPJBTL registration is approved. SLO by a certified LIT (inspection body).
Benchmark Q1 2025 market price, Rp 12,5 juta/kWp all-in. Actual figures depend on location, brand, and roof complexity.
| Home Scale | PLN Capacity | Capacity | All-in CapEx | Savings/Year | Payback |
|---|---|---|---|---|---|
| Small Home | R-1 900 VA | 2 kWp | Rp 25-30 jt | Rp 4-6 jt/thn | 6-7 thn |
| Standard Home | R-1 1300 VA | 3 kWp | Rp 35-45 jt | Rp 7-10 jt/thn | 6-9 thn |
| Large Home | R-1 2200 VA | 5 kWp | Rp 55-70 jt | Rp 12-18 jt/thn | 6-8 thn |
| Large R-2 Home | R-2 5500 VA | 8 kWp | Rp 90-110 jt | Rp 22-30 jt/thn | 5-7 thn |
Indicative estimate — our personal calculator is more accurate because it factors in your location's PSH, your specific PLN tariff, and your home's consumption pattern.
Start EstimatingAll our contractors must hold PLN SLO certification and have installed at least 50 residential systems.
Bandung, Jawa Barat
Serving: Bandung, Cimahi, Bandung Barat +1 more
Denpasar, Bali
Serving: Denpasar, Badung, Gianyar +2 more
Jakarta, DKI Jakarta
Serving: Jakarta, Tangerang, Bekasi +2 more
Total time 4-8 weeks — mostly in handling PLN SPJBTL and SLO. The physical rooftop installation takes only 1-2 days.
The EPC team visits your home, measures the roof, checks shading, reviews your last 6 months of PLN bills, and discusses target capacity.
Panel layout design, electrical single-line diagram, full BOM, and a final quotation with annual production estimate.
Online registration with PLN via the PLN Mobile app, a free PLN technical survey, and approval of the electricity contract amendment.
Mounting rail, panel, inverter, and DC/AC wiring installation through to initial commissioning. An installation team of 4-6 people per day.
SLO inspection by a LIT, replacement of the PLN meter with an EXIM smart meter, and the system officially goes live. Electricity production & export to PLN begins.
Answers based on actual PLN data, Q1 2025 market prices, and the latest regulation Permen ESDM 2/2024.
Rooftop solar suits homes that have: (1) a roof facing north/east/west with a minimum area of ~14 m² (for 2 kWp), (2) a PLN bill of at least Rp 500 ribu/month, and (3) an R-1 or R-2 PLN connection. Homes with partial roof shading (shading <30%) are still viable. If the roof is very narrow or shaded by tall buildings all day, results are less optimal — our on-grid calculator will show a realistic estimate for your specific conditions.
For an R-1 1300 VA home, the optimal capacity is usually 3 kWp with a total CapEx of Rp 35-45 juta (≈ Rp 12,5 juta/kWp all-in). For an R-1 2200 VA home, capacity rises to 5 kWp for a total of Rp 55-70 juta. The price already includes 550W mono PERC panels, a 3-5 kW on-grid inverter, roof mounting, cabling, EPC installation, and SLO handling. Q1 2025 market range: Rp 11-15 juta/kWp depending on panel brand and roof installation complexity (tile vs metal vs concrete).
The payback period for home rooftop solar ranges from 6-9 years, depending on the PLN tariff, location (PSH), and self-consumption rate. Homes with large PLN bills (Rp 1,5-3 juta/month) that consume a lot of electricity during the day can pay back faster (5-7 years). Homes whose consumption is mostly at night (overnight AC, electric stove) have a slightly longer payback because more electricity is exported to PLN at a 1:1 ratio. PLN tariffs have historically risen ~3,5%/year, so savings will keep growing over time.
A standard on-grid rooftop solar system automatically shuts off when PLN goes down — this is a mandatory safety feature (anti-islanding) under the IEEE 1547 standard so that PLN technicians stay safe while repairing the grid. If you need power during outages, there are 2 options: (1) add an LFP battery (making it a hybrid system, cost ~Rp 6,5 juta/kWh), or (2) use an inverter with a backup outlet feature (essential loads only). Without a battery, the rooftop system will automatically restart ~5 minutes after PLN returns to normal.
Yes, for on-grid rooftop solar you must register with PLN under Permen ESDM 2/2024. SPJBTL/amendment registration and the PLN technical survey are free (Rp 0). The only paid item is the Sertifikat Laik Operasi (SLO, operating-worthiness certificate) from an inspection body (LIT) — Rp 600 ribu-1,5 juta for residential <25 kVA. A trusted EPC contractor usually handles all of these permits as part of the all-in package. Total process from registration to an active EXIM meter: 5-15 working days.
Yes, solar panels are designed for all tropical weather. Tier-1 mono PERC panels carry a 25-year performance warranty (degradation <0,5%/year) and withstand heavy rain, intense heat, and even mild acid rain (IP67/IP68 rating on the junction box). Indonesia's tropical conditions are actually good for production: PSH (Peak Sun Hours) averages 4,2-5,8 hours/day. What needs upkeep: clean the panels of dust/bird droppings 2-3x a year, and make sure the mounting withstands wind loads >120 km/jam (important for Sulawesi/NTT regions).
No — if installed by a certified contractor. Modern mounting (tile hooks, L-foot rails, or non-penetrating ballast) is specifically designed not to damage the roof structure and to preserve waterproofing. Leak risk is actually lower because the panels add an extra layer of protection from rain. What's crucial: use an AESI-certified/PLN SLO EPC with a workmanship warranty of at least 2 years. Avoid cheap, uncertified contractors — that's the source of leak and short-circuit problems down the line.
Rule of thumb: 1 mono PERC 550W panel produces ~0,55 kWp. So a 3 kWp system needs ~6 panels (roof area ~14 m²), 5 kWp needs ~10 panels (~24 m²), and 8 kWp needs ~15 panels (~38 m²). Area requirement factor: ~2,3-2,5 m²/panel or ~7 m²/kWp. For a quick estimate based on your actual PLN bill — not a generic formula — use our on-grid calculator; its sizing already factors in your location's specific PSH from NASA POWER.
Have a factory or warehouse? See industrial solar solutions. Live in an area without PLN? Check off-grid solutions.
Estimate your home's savings in 60 seconds — free, no sign-up, no phone number required.